Lab 01 — Sequences, FASTQ and quality Lab

Lab 01 — Sequences, FASTQ and quality

Time: ~30 min · Before this: lab-00, Ch 41

You will take real Illumina reads apart by hand, derive the Phred scale rather than looking it up, and see for yourself why read quality decays along a read.

All outputs below are real, produced on the lab data during writing. Your numbers should match.

# GENOMICS is exported in lab-00. In a fresh shell, set it again:
#   export GENOMICS=/path/to/learn-genomics
cd "$GENOMICS"
source .venv/bin/activate
cd labs/data

1. The FASTQ record

Look at one:

gunzip -c ecoli_R1.fastq.gz | head -4
@SRR2584863.1 HWI-ST957:244:H73TDADXX:1:1101:4712:2181/1
TTCACATCCTGACCATTCAGTTGAGCAAAATAGTTCTTCAGTGCCTGTTTAACCGAGTCACGCAGG...
+
CCCFFFFFGHHHHJIJJJJIJJJIIJJJJIIIJJGFIIIJEDDFEGGJIFHHJIJJDECCGGEGII...

Four lines, always in this order:

LineContent
1@ then the read identifier
2The bases
3+, optionally repeating the identifier
4One quality character per base — same length as line 2

The identifier is not arbitrary. HWI-ST957:244:H73TDADXX:1:1101:4712:2181 encodes instrument, run, flowcell, lane, tile, and x–y coordinates of the cluster on the flowcell. When you later find that errors cluster on one tile or one edge of the flowcell, this is the field that tells you.

The four-line record is a convention, not a guarantee. Sequence and quality may in principle wrap across lines, and the @ that starts a header is also a legal quality character — so you cannot reliably parse by looking for lines beginning with @. Parsing in strict groups of four is what every real tool does. Writing your own line-based parser is a rite of passage that ends in a subtle bug.

2. Derive the Phred scale

Quality is encoded as one ASCII character per base. The rule:

Q = −10 log₁₀(P_error), and the character is chr(Q + 33).

The + 33 offset exists so that the values land in printable ASCII. Work it out:

python -c "
for q in (10,20,30,40):
    print(f'Q{q:<3d} P(err)={10**(-q/10):<8.4f} accuracy={100*(1-10**(-q/10)):.2f}%  char={chr(q+33)!r}')
"
Q10  P(err)=0.1000   accuracy=90.00%  char='+'
Q20  P(err)=0.0100   accuracy=99.00%  char='5'
Q30  P(err)=0.0010   accuracy=99.90%  char='?'
Q40  P(err)=0.0001   accuracy=99.99%  char='I'

Q30 — "one error in a thousand bases" — is the usual quality target, and now you know exactly what it asserts.

The statistics here. A Phred score is a probability written on a log scale: Q = −10 log₁₀ P(error), so Q30 asserts P(error) = 0.001 for that single base call. That is not a frequency you could ever check on one base — it is the instrument's degree of belief given the signal it saw, which is the reading of probability that S1 sets up. How to read it: every 10 points of Q divides the error probability by ten, and the claim is only checkable in aggregate — among all bases the instrument labels Q30, about 1 in 1,000 should really be wrong. That is an assumption, not a guarantee: Q is a model's output, and an uncalibrated model produces confident wrong numbers, which is exactly what the Phred+64 trap below does to it.

The historical trap. Older Illumina pipelines (pre-1.8) used an offset of 64, not 33. Feed Phred+64 data to a tool expecting Phred+33 and every quality is inflated by 31 — nothing crashes, and every downstream number is wrong. If you ever see quality characters below ! (33) or a suspiciously high mean, suspect the encoding. Modern data is Phred+33; archival data may not be.

3. Basic statistics

seqkit stats ecoli_R1.fastq.gz ecoli_R2.fastq.gz
file               format  type  num_seqs     sum_len  min_len  avg_len  max_len
ecoli_R1.fastq.gz  FASTQ   DNA    100,000  15,000,000      150      150      150
ecoli_R2.fastq.gz  FASTQ   DNA    100,000  15,000,000      150      150      150

Uniform 150 bp — characteristic of Illumina, where read length is set by the number of sequencing cycles, not by the molecule. Long-read platforms give a broad length distribution instead; that difference alone tells you which technology produced a file.

Compute the expected before you align. 100,000 reads × 2 mates × 150 bp = 30,000,000 bp of sequence against a 4,629,812 bp genome:

30,000,000 ÷ 4,629,812 ≈ 6.5×

Doing this arithmetic first is a habit worth forming. If your alignment later reports a depth wildly different from your prediction, something is wrong — and you will only notice if you had a prediction.

The statistics here. 6.5× is an expected depth — an average over the genome, not a promise about any particular base. The standard model (Lander–Waterman) makes the number of reads covering a given base Poisson with λ = depth, which is the right default because there are enormously many reads and each has a tiny chance of landing on that base (S2). Reading it that way gets you the spread for free, because Poisson has one parameter and its variance equals its mean: sd = √6.5 ≈ 2.5, so per-base depth runs from about 2 to 12, and e^(−6.5) ≈ 0.15% of bases are expected to get no read at all. Real coverage is worse than Poisson — S2 measures a variance-to-mean ratio of 1.49 on the alignment you build in lab 02, because λ is not constant along a genome.

4. GC content — a first sanity check

seqkit fx2tab -nlg ecoli_R1.fastq.gz | awk '{s+=$NF; n++} END {printf "reads GC:     %.2f%%\n", s/n}'
seqkit fx2tab -nlg rel606.fa       | awk '{printf "reference GC: %.2f%%\n", $NF}'
reads GC:     50.61%
reference GC: 50.77%

Within 0.16 percentage points. That agreement is meaningful: it says the library is not grossly biased and the reads plausibly come from this organism. A large discrepancy would suggest contamination, adapter read-through, or severe amplification bias against GC-extreme regions.

The statistics here. Both numbers are estimates of the same underlying quantity, and comparing them is a bias check rather than a test. With 100,000 reads the sampling error on the read GC is on the order of a hundredth of a percentage point — far below the 0.16 pp gap — so what is left over is systematic, not noise: mild GC bias in library prep, adapter, or unaligned contamination. Sampling error shrinks as 1/√n and bias does not shrink at all, which is the distinction S3 builds the chapter around. So read this comparison for the size of the difference, never for whether it is "significant": at n = 100,000 every difference is significant, and only its magnitude tells you whether it matters.

E. coli at ~50.8% GC is unremarkable. Genomic GC ranges from under 20% to over 70% across bacteria, and it is one of the fastest ways to notice you have the wrong organism.

5. Watch quality decay along the read ★

This is the most instructive measurement in the lab. Compute mean quality per sequencing cycle:

python - <<'PY'
import gzip
sums = [0]*150; n = 0
with gzip.open('ecoli_R1.fastq.gz', 'rt') as f:
    for i, line in enumerate(f):
        if i % 4 == 3:                        # line 4 of each record
            for j, c in enumerate(line.strip()[:150]):
                sums[j] += ord(c) - 33        # Phred+33 decode
            n += 1
            if n >= 20000: break
for cyc in (1, 10, 25, 50, 75, 100, 125, 150):
    q = sums[cyc-1]/n
    print(f"cycle {cyc:3d}: Q{q:5.1f}  P(error) = {10**(-q/10):.5f}  {'#'*int(q/2)}")
PY
cycle   1: Q 32.4  P(error) = 0.00057  ################
cycle  10: Q 38.0  P(error) = 0.00016  ##################
cycle  25: Q 39.0  P(error) = 0.00013  ###################
cycle  50: Q 35.7  P(error) = 0.00027  #################
cycle  75: Q 31.8  P(error) = 0.00066  ###############
cycle 100: Q 28.4  P(error) = 0.00143  ##############
cycle 125: Q 26.4  P(error) = 0.00230  #############
cycle 150: Q 22.9  P(error) = 0.00514  ###########

The statistics here. Each printed Q is a sample mean — the average quality at that cycle over 20,000 reads — and it estimates the true per-cycle mean for this library (S3 on estimators and standard error). Two things about reading it. The 20,000 are not a random sample of the file, just whatever sits at the top of it, so a problem confined to a few flowcell tiles would appear here as if it were a property of the whole run — sampling error is tiny at this n, but an unrepresentative sample is not sampling error. And because Q is a logarithm, averaging Q averages log probabilities: the printed P(error) is the geometric mean of the per-base error probabilities, which is always at or below their arithmetic mean. The true error rate at each cycle is therefore somewhat worse than the number shown, and increasingly so as the spread of qualities widens towards the end of the read.

Two features, both mechanistic:

Quality rises over the first ~25 cycles. The instrument calibrates its base-calling model on early cycles, and cluster identification is still being refined. The first few bases are slightly less reliable than cycle 25.

Quality then falls steadily. This is dephasing. Each cluster is ~1,000 supposedly identical molecules read in lockstep, and the signal is their summed fluorescence. At every cycle a small fraction of molecules fail to incorporate, or incorporate two bases. Those molecules fall out of step, and since the errors accumulate, the fraction out of grows with every cycle. The summed signal gets progressively noisier until it is no longer callable.

The error rate at cycle 150 (0.51%) is forty times that at cycle 25 (0.013%), the best cycle in the read, and nine times that at cycle 1 (0.057%). This is why Illumina read length is capped where it is: not by chemistry cost but by the point at which dephasing makes the signal unusable. It is also why trimming low-quality read ends is standard, and why paired-end sequencing helps — the second read starts fresh from the other end of the fragment.

6. Find the adapters

Reads from short fragments sequence past the insert into the adapter.

gunzip -c ecoli_R1.fastq.gz | awk 'NR%4==2' | grep -c "AGATCGGAAGAGC" || true

AGATCGGAAGAGC is the start of the standard Illumina TruSeq adapter. A high count means many fragments were shorter than 150 bp and need trimming before alignment; adapter sequence does not match the genome and will either fail to align or align badly.

7. Duplicates

gunzip -c ecoli_R1.fastq.gz | awk 'NR%4==2' | sort | uniq -d | wc -l

Identical sequences are usually — the same original fragment amplified and sequenced repeatedly. They are not independent observations, so they inflate apparent depth without adding evidence, and they will bias if not marked. Note this counts exact duplicates only; real duplicate marking uses alignment position, which catches duplicates that differ by a sequencing error.


Check yourself

1. A quality string contains the character #. What is the base's error probability?

Answer

ord('#') = 35, so Q = 35 − 33 = 2.

P(error) = 10^(−2/10) = 10^(−0.2) ≈ 0.63

A 63% chance of being wrong — essentially no information. # is Illumina's conventional marker for a base it could not call at all, and you will see runs of them at the ends of poor reads. Look back at the first record in section 1: it ends in a long run of #.

2. You are told a file has mean quality Q65. What is actually going on?

Answer

Q65 corresponds to an error probability of 10^(−6.5) ≈ 3 × 10⁻⁷, which no sequencing platform achieves per base. The file is almost certainly Phred+64 encoded and being decoded as Phred+33, inflating every value by exactly 31. Q65 − 31 = Q34, which is entirely plausible.

The diagnostic: check the range of quality characters actually present. Phred+33 data uses ! (33) upward; Phred+64 data starts at @ (64) and never contains characters below it.

3. Why does read quality improve over the first 25 cycles before declining?

Answer

The instrument's base-calling model is calibrated on early cycles and cluster identification is still being refined, so the first bases are called with a less well-tuned model. Once calibration settles, quality peaks — and then dephasing takes over, because the fraction of molecules within each cluster that have fallen out of step grows monotonically with cycle number. The result is the characteristic rise-then-fall profile you measured.

4. You predicted 6.5× . The alignment reports 6.0×. Is that a problem?

Answer

No — and knowing why is the point. Your prediction assumed every base of every read is placed on the genome. Almost every read is: 99.27% of them map (lab-02 §3). But only 93.1% of the bases align. The difference is soft-clipping — 1,851,906 bases, 6.17% of the 30,000,000 you sequenced, are trimmed off read ends by the aligner because they do not match (adapter remnants and low-quality 3′ tails), and clipped bases contribute no depth. Reads that fail to map entirely account for only 217,650 bases, 0.73%.

Reads mapped and bases aligned are different measurements, and coverage is built from the second. A pipeline can report a superb mapping rate and still lose 7% of its data.

A discrepancy in the other direction — measured depth much higher than predicted — would be more suspicious, typically meaning the reference is smaller than you think or reads are piling up in a repeat.